# Spec Delta: fingerprint-wizard
## ADDED Requirements
### Requirement: Scanner availability is shown and gates capture
The wizard SHALL consume fpagent's `fprint-device-status`
`{available, device, captureAgentId}` event and SHALL distinguish the agent
being offline (socket not connected), connected with no supported reader
attached (`available` false), and ready (`available` true). Until a status is
received, availability SHALL be treated as unknown. The wizard SHALL NOT start a
capture while no supported reader is attached, SHALL re-enable capture when a
reader becomes available, and SHALL clear availability when the agent
disconnects. Availability means "a supported reader is attached"; it does not
guarantee a capture will succeed.
#### Scenario: Reader attached on connect
- **WHEN** the page connects and fpagent reports `fprint-device-status` with
`available: true`
- **THEN** the wizard shows the agent ready and leaves capture enabled
#### Scenario: No reader attached on connect
- **WHEN** the page connects and fpagent reports `fprint-device-status` with
`available: false`
- **THEN** the wizard shows that the scanner is not connected, explains captures
are disabled, and disables the capture controls
#### Scenario: Unplug blocks capture
- **WHEN** fpagent reports `available: false` while the operator is capturing or
between captures
- **THEN** the wizard disables the capture controls and a capture attempt is
refused
#### Scenario: Replug re-enables capture
- **WHEN** fpagent reports `available: true` after the reader is reconnected
- **THEN** the wizard re-enables the capture controls
#### Scenario: Status absent or old agent
- **WHEN** the connected agent never reports `fprint-device-status`
- **THEN** availability stays unknown and the wizard does not block capture
#### Scenario: Disconnect clears availability
- **WHEN** the agent socket disconnects
- **THEN** the wizard shows the agent offline and does not present the reader as
available